Thermal Map Sensor


Monitor temperature differential between front and rear of your cabinet.

  • Temperature only

  • Dual Temperature and Humidity

  • Check for cabinet hotspots










Detect Hotspots In Your Cabinet

Datacenter monitoring with thermal map sensors helps identify and eliminate hotspots in your cabinets by identifying areas where the temperature differential between the front and rear is too high.


AKCP Thermal Map Sensor consists of a string of 6 temperature sensors and an optional 2 humidity sensors. Pre-wired to be easily installed in your cabinet, they are placed at the top, middle, and bottom – front and rear of the cabinet. This configuration of sensors monitors the air intake and exhaust temperatures of your cabinet, as well as the temperature differential from the front to the rear. Use thermal map sensors to identify cabinet hot spots and problem areas. AKCP Thermal Map Sensors are easy to install, come pre-wired, and are ready to mount with magnetic, cable ties, or ultra-high bond adhesive tape to hold them in position on your cabinet. Mount each sensor on the front and rear doors of your perforated cabinet so they are exposed directly to the airflow in and out of the rack. On sealed cabinets, they can still be mounted on the inside and give the same monitoring of temperature differential between front and rear, and ensure that airflow is distributed across the cabinet. AKCP Thermal Map Sensor connects to AKCP sensorProbe+ base units. Extendable up to a maximum of 15 meters cable length, you can monitor multiple cabinets from a single IP address. Up to 16 thermal maps can be connected to a single SPX+. Example of rack maps installed in a cabinet, 3 sensors at the front, and 3 at the rear.


Advantages

Advantages Of Thermal Map Sensors

Obstructions Within The Cabinet

Cabling or other obstructions can impede the flow of air causing high-temperature differentials between the inlet and outlet temperatures. The cabinet analysis sensor with pressure differential can also help analyze airflow issues.

Server And Cooling Fan Failures

As fans age, or fail, the airflow over the IT equipment will lessen. This leads to higher temperature differentials between the front and rear.

Insufficient Pressure Differential To Pull Air Through The Cabinet

When there is an insufficient pressure differential between the front and rear of the cabinet, airflow will be less. The less cold air flowing through the cabinet, the higher the temperature differential front to rear will become.

Power Usage Effectiveness (PUE)

When the data is combined with the power consumption from the in-line power meter you can safely make adjustments in the data center cooling systems, without compromising your equipment, while instantly seeing the changes in your PUE numbers.

Rack Map Display

Multiple Cabinet